Nnfluke 73 iii multimeter pdf files

These meters are over voltage protected against transient. Daily, weekly and monthly rates are available on select items. Introduction this document contains specifications, general maintenance information, and performance tests for the. Resistance, continuity, frequency, capacitance, and diode test measures 10 a 20 a overload for 30 seconds large white led backlight to work in poorly lit areas compact ergonomic design for onehanded operation compatible with optional magnetic hanger toolpak truerms for accurate measurements on nonlinear loads. Fluke 73iii digital multimeter sales, rent, calibration. Comes in a compact, rugged, ergonomic design and is easytouse. All pushbutton features are available for a standard dc volts reading. Use a fluke 73 series ii multimeter free pdf file sharing. Voltage frequency is specified from 2 hz to 100 khz. Cat ii overvoltage installation category per iec 10101. Connect the common test lead before you connect the live test lead. If you are not sure how accurate your digital multimeter measurement is, find its accuracy specifications in the instruction manual, and then read this to get the rest of the story. Also set the negative wire to ground and the positive to the point where you are measuring the current.

For example, a cat iii v meter has superior protection compared to a cat iii. Technical data fluke 115 multimeter features include. All ac voltage and ac current ranges are specified from 5 % of range to 100 % of range. Its rugged, especially in its bright yellow holster, and has so many thoughtful features. Digital multimeters fluke digital multimeters dmms are on more tool belts, finding more problems, than any other comparable test tools. In many years of service they have become the preferred models for a large number of professionals. Its actually not hard to learning to use a fluke multimeter but it can take some time if youve never done used anything like it before. Most handheld dmms are more accurate than you might expect, including the least expensive models. Electromagnetic compatibility and 7323eec, the low. Perform the calibration procedure described under the heading calibration adjustment in this document. The meter is a handheld 312 digital multimeter for measuring dc and ac voltage, dc current, resistance, diode, and continuity test with battery operated. Most meters log and graph data right on the screen.

Get fluke 73 iii multimeter manual pdf file for free from our online library pdf file. Fluke multimeter environmental resources engineering. Fluke 179 true rms digital multimeter with builtin. The lcd screen with 16mm display gives clear readings even in low light when the back light can be switched on. When choosing a multimeter, first determine cat levels you will be operating. I learned how to use a fluke multimeter simply multimeters. Series iii multimeter istruzioni w informazioni sulla sicurezza. Fluke 79 iii calibration information manual pdf download. On sale 733 we take purchase orders and can provide special school. Servicing a fluke 12 multimeter martinjonestechnology. The 77 iii has all the features and functions for a wide range of industrial applications packaged in an ergonomic case with integrated holster. When i first got my meter, i was pretty much clueless as to its functionality. Rough handling and high voltage are tough on a meter.

There are also frequently asked questions, a product rating and feedback from users to enable you to optimally use your product. The used equipment exchange network is an international supplier of various types of computers and parts, such as. Use them in the field or on the bench to troubleshoot and diagnose electrical measurements, appliance testing, lighting systems, electricity meters and more. Versatile meter for maintenance, field service and bench repair. Fluke corporation 733 series iii 600volt digital multimeter. Fluke 107 esp palmsized digital multimeter, cat iii, 600 v model. Then hold the probes against the resistor legs with the same amount of pressure you when pressing a key on a keyboard. The fluke 73 and 77 offer exactly the right fit for a wide range of measurements. Now when you purchase a fluke digital multimeter, not only do you get a test tool known for its unsurpassed quality. Digital multimeter troubleshooting and repair simply. Average responding measures both amps and milliamps removable high impact holster manual or autoranging feature 73iii 77iii features a default autorange mode thats easy to change to manual by simply touching the range button.

How to use a multimeter for the beginner sciencing. Save this book to read fluke 73 iii multimeter manual pdf ebook at our online library. Jm test rental options can help you save capital, get the latest technology, and expand your capabilities. Fluke digital multimeters combine multiple meter functions into one.

Introducing the rugged new fluke 70 series iii digital multimetersp. A multi meter is small portable device that can be used to measure voltage, current resistance, or to test diodes. Save, collaborate and share measurements instantly with your team anytime, from anywhere. Set the multimeter to the ac or dc modes to begin measuring current. Fluke 70 and 170 series digital multimeter specifications. The 73 iii is perfectly suited for many electronic applications and has the classic 70 series design with removable holster. Being on the other side of the pond and not knowing was an avo model 8 was, i did a search for it. Fluke 87 fusible resistor posted on july 30, 20 by modemhead properlydesigned multimeters that are suitable for professional and trade use have a number of components, usually near their input jacks, that are for the sole purpose of protecting both the user and secondarily the multimeter itself from overvoltage and overcurrent situations. Hunting down the ghosts in the past, tracking down such a voltage indication could send the technician off on a time. Controllare che i cavetti di prova e il commutatore rotativo siano nella posizione adeguata alla. One of my mostused tools on the workbench is my fluke 12 multimeter. Multimeters bench multimeters and handheld meters on sales. Made to last and deliver years of reliable results, this handy model is built tough inside and out, making it an allaround performer.

Within a category, a higher voltage rating denotes a higher transient withstand rating. The fluke 179 truerms digital multimeter has the features needed to find most electrical and hvac problems. The fluke corporation series iii 73 600volt digital multimeter offers exactly the right fit for a wide range of. Find your used multimeters at, the online marketplace for used test and measurement equipment. Thus, a multimeter designed to a cat iii standard is resistant to much higher energy transients than one designed to cat ii standards. New fluke 117 digital multimeter drives the ghosts out of. When using the probes, keep your fingers behind the finger guards. The fluke corporation series iii 73 600volt digital multimeter offers exactly the right fit for a wide range of measurements. Fluke multimeter fluke 73 iii multimeter user manual. But the new fluke 70 series iii dmms take it all in stride. Work faster, safer and easier with fc wireless test tools. Below you can view and download the pdf manual for free.

Never rotate the dial of the multimeter while it is still connected to the circuit as doing so may damage the instrument. Be sure the test leads and rotary switch are in the correct position for the desired measurement. For example, an electrician working in cat iii and cat iv areas can choose a meter rated cat iii v cat iv 600 v. Cat iii measurements performed in the installation for a buil ding. Multimeter measurements on variable frequency drives using. Access equipment history building a database of equipment health and baselines with cloud backup.

With overvoltage protection to guard against spikes up to 6 kv, and safety ratings to prove it. Every fluke 77iii and 73iii meter comes packaged with tl75 test leads, separate holster fluke 73iii, 9 v battery installed and manual. Never use the meter if the meter or test leads look damaged. To avoid electric shock, do not perform any servicing unless you are qualified to do so.

A digital multimeter dmm may look complicated and intimidating at first glance, but once you understand the display, dial, and port panel, youll have a better grasp of dmm basics. Current frequency is specified from 2 hz to 30 khz. Series iii multimeter loohms calibration loohms calibration note for the fluke 26 or 79 series iii with a serial number greater than 71220000, use the following procedure. Both models come with the unique lifetime warranty. This preownedrecycled fluke 73 iii digital multimeter 73iii was described to the best of our knowledge and it is offered asis. If the field items in stock shows zero, the product is no longer available. Ordering information fluke733 digital multimeter fluke773 digital multimeter fluke 73iii and 77iii digital multimeters classic general purpose multimeters specifications 73iii and 77iii.

Fluke 733 600v cat ii industrial multimeter tequipment. This palmsized digital multimeter is ideal for troubleshooting and is small enough to fit in a shirt pocket or work bag. Pick out a random resistor and set the multimeter to the 20k. But the fluke 73 and 77 series iii dmms take it all in stride. Ive had it almost 20 years, and its my favourite meter because it was clearly designed by someone who had to fix things. New fluke 117 digital multimeter drives the ghosts out of the attic and the electric circuits the wet, dirty plant environment, the potential problems were many. Accuracy is specified for a period of one year after calibration, at 18 c to 28 c 64 f to 82 f with relative humidity to 90 %. Ac conversions are accoupled, average responding, and calibrated to the rms value of a sine wave input. Then choose a meter with a voltage rating higher than the maximum voltage you will be testing at each cat level. Simple to use with significant improvements like truerms, frequency, capacitance, temperature and minmax record. Extremely rugged overmolded case provides body armor for your meter.

Use graphing to show changes in measurements, allowing you to graph and show problems instantly. Set up the meter for dc voltage measurement as shown in. Safety information w to avoid damage to the meter, electric shock or injury. Digital multimeter troubleshooting and repair april 22, 2014 june 20, 2014 george 2 comments digital multimeter repair, digital multimeter troubleshooting, dmm help, repairing dmm your digital multimeter should last for a number of years with reasonable care, but there may come a time when you multimeter malfunctions and youll have to. Connect the clamp to the 289s common and 400 ma input jacks. W to avoid damage to the meter, electric shock or injury. Observe the display to obtain the current in amperes. Fluke 7377 series iii digital multimeter crawford tool. Start with the multimeter and future proof your investment.

This multimeter is characterized by a compact rugged construction with protective holster and stand. The engineering department at hsu has a set of type 73 iii series iii hand held digital multi meter manufactured by fluke. Features include sophisticated ad converter in conjunction with overload protection. Use caution when working with voltages above 30 v ac rms, 42 v ac peak, or 60 v dc. The 3000 fc multimeter displays the meter measurement, plus readings from up to three wireless modules, connect to your smart phone to see reading directly on your phone. Vintage pc, at, xt, apple, mac, unix, macintosh, laptop and ps2.